Switching Power Supply / SMPS / LED Driver / Waterproof Power Supply / Switch Mode Power Supply / AC DC Power Supply / LED Power Supply
Δ 500W single output switching power supply with pfc function SP-500 series
Features:
Universal AC input / full range.
Built active pfc function, pf>0.95
Protections: Short circuit / over load / over voltage / over temperature
Forced air cooling by built-in DC fan.
Built-in cooling fan on-off control.
Built-in remote on-off control.
Built-in remote sense function.
Our product:
Single output S series
Dual output D series
Triple output T series
Quad output Q series
Miniature size MS, RS, NES series
Witch PFC function SP series
DIN Rail DR series
LED Driver (waterproof) SV, FY series
Open frame PS, PD, PT series
DC/DC converter SD series
WMP and AD series power supply
For more, please visit our website.
SP-500 specification
MODEL
SP-500-12
SP-500-13.5
SP-500-15
SP-500-24
SP-500-27
SP-500-48
OUTPUT
DC VOLTAGE
12V
13.5V
15V
24V
27V
48V
RATED CURRENT
40A
36A
32A
20A
18A
10A
CURRENT RANGE
0 ~ 40A
0 ~ 36A
0 ~ 32A
0 ~ 20A
0 ~ 18A
0 ~ 10A
RATED POWER
480W
486W
480W
480W
486W
480W
RIPPLE & NOISE (max. )
240mVp-p
240mVp-p
240mVp-p
240mVp-p
200mVp-p
300mVp-p
VOLTAGE ADJ. RANGE
10 ~ 13.2V
12 ~ 15V
13.5 ~ 18V
20 ~ 26.4V
26 ~ 32V
41 ~ 56V
VOLTAGE TOLERANCE
± 1.0%
± 1.0%
± 1.0%
± 1.0%
± 1.0%
± 1.0%
LINE REGULATION
± 0.5%
± 0.5%
± 0.5%
± 0.5%
± 0.5%
± 0.5%
LOAD REGULATION
± 0.5%
± 0.5%
± 0.5%
± 0.5%
± 0.5%
± 0.5%
SETUP, RISE, HOLD TIME
1500s, 50ms, 24ms
INPUT
VOLTAGE RANGE
88 ~ 264VAC 124 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR
PF> 0.95/115 PF> 0.95> 240VAC at full load
EFFICIENCY (Typ. )
84%
84%
83%
85.5%
86.5%
87%
AC CURRENT
7A/115V 3.5A/230V
INRUSH CURRENT (max. )
18A/115V 36A/230V
LEAKAGE CURRENT
< 3.5mA / 240VAC
PROTECTION
OVERLOAD
105 ~ 135% of rate load
Protection type: Fold back current limiting, recovers automatically after fault condition is removed
OVER VOLTAGE
13.8 ~ 16.2V
15.5 ~ 18.2V
18 ~ 21V
27.6 ~ 32.4V
31 ~ 36.5V
57.6 ~ 67.2V
Protection type: Hiccup mode, recovers automatically after fault condition is removed.
FAN CONTROL, O. T. P.
RTH1 or RTH2≥ 50º C FAN ON, ≤ 45º C FAN, ≥ 70º C output shut down
FUNCTION
REMOTE CONTROL
RC+/RC-: Short = power on; Open = power off
ENVIRONMENT
WORKING TEMP.
-10 ~ +50º C (Refer to output load derating curve), 20 ~ 90% RH non-condensing
WORKING HUMIDITY
20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY
-20 ~ +85º C, 10 ~ 95% RH
TEMP. COEFFICIENT
± 0.03%/º C (0 ~ 50º C)
VIBRATION
10 ~ 500Hz, 2G 10min. /1cycle, 60min. each along X, Y, Z axes
SAFETY & EMC
SAFETY STANDARDS
Design refer to UL1950, TUV EN60950-1
WITHSTAND VOLTAGE
I/P-O/P: 3KVAC I/P-FG: 1.5KVAC O/P-FG: 0.5KVAC
ISOLATION RESISTANCE
I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC
EMI CONDUCTION & RADIATION
Compliance to EN55022 (CISPR22) Class B
HARMONIC CURRENT
Compliance to EN61000-3-2, -3
EMS IMMUNITY
Compliance to EN61000-4-2, 3, 4, 5, 6, 8, 11; ENV50204, Light industry level, criteria A